DLSGeneral Industrial Control

DLS Series Industrial Chiller

Sub-zero industrial cooling · reliable round-the-clock operation

Temperature control across chemical, pharmaceutical, food and machining applications.

  • Temperature range-25℃ / -40℃ – RT
  • Cooling capacity0.5~55kW
  • ProtectionMulti-level alarms
  • CommunicationRS485 Modbus RTU
  • CondensingAir / water cooled
DLS Series Industrial Chiller

Overview

The DLS industrial chiller serves external applications requiring rapid cool-down, and industries that must hold low temperature: chemical, biological, pharmaceutical, freeze-drying, food and defence. Two temperature bands are available, -25℃–RT and -40℃–RT. The circulation circuit uses a fully sealed SUS304 design, with air- or water-cooled condensing and optional explosion-proof construction.

Features

  • 01Reliable, designed for 24/7 continuous duty
  • 02Fully sealed SUS304 circulation circuit
  • 03Wide model range with custom builds supported
  • 04Optional explosion-proof construction (Exp / Exd)

Typical Applications

  • Chemical reactor and crystallisation cooling
  • Low-temperature source for pharmaceutical and freeze-drying
  • Coating and filling temperature control in lithium-battery lines
  • Process cooling for machining and food industries

Working Principle

Fill portBuffer tankLevel gaugeCirculation pumpEvaporatorUser equipmentTSupply temp.TReturn temp.CompressorCondenserFilter drierExpansion valve
※ Note: the flow diagram is simplified and may differ from the actual unit.

Model Designation

DLSB0.5WN
  1. 1. Product series code
  2. 2. Temperature code: A -10℃–RT, B -25℃–RT, C -40℃–RT; 5℃–RT is not marked
  3. 3. Capacity code: cooling capacity at 5℃ above the minimum outlet temperature, e.g. 0.5 kW at -20℃. For industrial and precision chillers it is the capacity at a 20℃ outlet; for screw chillers it is the compressor code
  4. 4. Condensing: W for water-cooled; air-cooled is not marked
  5. 5. Non-standard code: see the non-standard code rules; omitted if not required

Specifications

Data taken from the GPTECH product catalogue. Contact us for other models or custom specifications.

SpecificationsDLS Series -25℃–RT

ModelDLS-B05DLS-B1DLS-B1.5DLS-B2.5DLS-B3.5DLS-B5DLS-B7DLS-B10DLS-B15DLS-B20DLS-B25
Main applicationFor external applications requiring rapid cool-down and sustained low temperature: chemical, biological, pharmaceutical, freeze-drying, food and defence industries.
Temperature range-25℃–RT
Cooling capacity kW0℃1.52.53.55.8811.51525354555
-10℃0.751.52.33.85.37.510.51522.53037.5
-20℃0.511.52.53.55710152025
Max. pump flow L/min2030305050110110140140200250
Max. pump head m1525253535404050503535
Buffer tank volume L10203040506080100150200250
Controlled variableUnit outlet temperature control
Control accuracyOn/off control, settable to ±2℃ (with optional electric-heating precision model, accuracy up to ±0.1℃)
CommunicationRS485 interface as standard, Modbus RTU protocol
Temperature feedbackOutlet temperature (PT100)
ProtectionReal-time status display and automatic fault diagnosis with multi-level alarms: earth leakage, power failure, circulation-pump overload, compressor overload, high/low refrigerant pressure, over-temperature and sensor fault.
Circulation circuitSUS304, fully sealed circuit design
RefrigerantR404A
Port sizeG1/2G3/4G3/4G3/4G3/4G1G1DN32DN32DN40DN50
Water-cooled (suffix W)Flow m³/h0.60.81.11.52.234.2691215
Water temp.Flow rates are calculated at 20℃ water temperature. Cooling water inlet must stay between 5℃ and 33℃, otherwise unit operation is affected.
Pressure2–4.5 bar
Port sizeG1/2G1/2G1/2G3/4G3/4G1G1DN32DN32DN40DN50
Dimensions, water-cooled cm65×45×12565×45×12565×45×12575×55×14575×55×14585×55×14590×65×155115×75×175125×85×195155×100×225155×100×225
Dimensions, air-cooled cm65×45×12565×45×12575×55×14585×55×14585×55×14590×65×155115×75×175125×85×195155×100×225200×120×255220×150×225
Weight, air-cooled kg12513516519522529541558589512351855
EnclosurePowder-coated cold-rolled steel (standard RAL 9016, SUS304 optional)
Power supply ph/v/Hz1/220/503/380/50
Connected load kW1.522.33468.511152228
OptionsExplosion-proof design (pressurised type suffix Exp, flameproof type suffix Exd)

※ Notes

  1. Cooling capacities are based on 20℃ cooling-water inlet temperature; air-cooled units at 20℃ ambient.
  2. Flow and head figures apply to water at 20℃; pump performance varies with the density and temperature of the medium.
  3. Buffer tank volumes are indicative and can be adjusted to the required ramp rate and thermal storage.
  4. Only part of the product range is listed. For other models or customised requirements please contact our sales team. Specifications are subject to change without notice.

Need selection advice for the DLS?

Send us your temperature, heat load and flow requirement — an engineer will reply within one working day