PTLQ Series Gas Chiller
Gas cooling and thermostatting · -135℃ to +225℃
Cools process gases such as nitrogen and compressed air; widely used in wafer test and laser equipment.
- Temperature range-135℃ ~ +225℃
- Gas capacity30~300 m³/h
- Cooling capacity0.5~5.5kW
- Control accuracy±0.5℃ (±0.1℃ option)
- ControlAdaptive PID

Overview
The PTLQ gas chiller cools process gas and can also heat or hold it at a set point. The gas is typically dry compressed air or an inert gas such as nitrogen or argon; the inlet may be at ambient or elevated temperature and is brought down to the target. For wafer-test thermal chucks it offers clear advantages over conventional liquid cooling: easier handling, better hygiene and safety, lower cost and no odour. An optional IoT module allows data, alarms and remote operation from a mobile app.
Features
- 01-135℃ to +225℃, custom ranges available
- 02High-efficiency exchanger: ambient to -80℃ in as little as 5 minutes
- 03Optional precision control up to ±0.1℃
- 04Optional cold-recovery unit improves efficiency
- 05Optional automatic inlet-flow control and measurement
- 06Adaptive PID delivers optimal control without retuning
- 07Optional IoT remote monitoring via mobile app
Typical Applications
- Low-temperature gas for wafer-test thermal chucks
- Low-temperature chip testing
- Localised cooling for laser equipment
- Low-temperature debonding of LCD touch panels
- Material performance testing
- Thermal-sink experiment control
- Crystallisation system control
Working Principle
Model Designation
- 1. Product series code
- 2. Temperature code (minimum gas outlet temperature): A -10℃, B -25℃, C -40℃, D -60℃, F -80℃, H -100℃, J -120℃, L -150℃
- 3. Capacity code: cooling capacity at 5℃ above the minimum temperature, e.g. 0.5 kW at -55℃
- 4. Maximum gas throughput
- 5. Heating: built-in gas heater delivering outlet temperatures up to 200℃
- 6. Condensing: W for water-cooled; air-cooled is not marked
- 7. Non-standard code: see the non-standard code rules; omitted if not required
Specifications
Data taken from the GPTECH product catalogue. Contact us for other models or custom specifications.
SpecificationsPTLQ Series -40℃
| Model | PTLQ-C05-30 | PTLQ-C1-60 | PTLQ-C1.5-90 | PTLQ-C2.5-150 | PTLQ-C3.5-200 | PTLQ-C5.5-300 | |
|---|---|---|---|---|---|---|---|
| Min. process temperature | -40℃ | ||||||
| Gas capacity m³/h | 30 | 60 | 90 | 150 | 200 | 300 | |
| Cooling capacity kW @-35℃ | 0.5 | 1 | 1.5 | 2.5 | 3.5 | 5.5 | |
| Heating power kW (option) | 0.9 | 1.8 | 1.8 | 3 | 3.5 | 5.5 | |
| Control accuracy | ±0.5℃ (requires the optional heater; without it the unit runs uncontrolled and simply reaches the designed minimum outlet temperature) | ||||||
| Control system | PLC controller with intelligent PID temperature module for precise control and real-time display | ||||||
| HMI | 7-inch colour touchscreen, Chinese/English UI, intuitive operation, displays and logs temperature curves and test data | ||||||
| Controlled variable | Unit outlet temperature control | ||||||
| Communication | Modbus RTU protocol over RS485 | ||||||
| External inputs | External temperature sensor port, USB data port | ||||||
| Temperature feedback | PT100 feedback on the heat-transfer medium (inlet and outlet temperature) | ||||||
| Protection | Real-time status display and automatic fault diagnosis with multi-level alarms: power failure, compressor overload, high/low refrigerant pressure, heater over-temperature, temperature module fault and sensor fault. | ||||||
| Heat-exchanger material | SUS304 | ||||||
| Heat-exchanger rating | ≥3 MPa | ||||||
| Inlet gas requirement | Nitrogen or 3–7 bar compressed air; must be dried, with a dew point below the minimum process temperature | ||||||
| Refrigerant | R404A | ||||||
| Port size | 10mm卡套 | G1/2 | G3/4 | G1 | G1-1/4 | DN50 | |
| Water-cooled (suffix W) | Flow m³/h | 0.6 | 1.2 | 2.1 | 2.8 | 3.5 | 5.5 |
| Water temp. | Flow rates are calculated at 20℃ water temperature. Cooling water inlet must stay between 5℃ and 30℃, otherwise unit operation is affected. | ||||||
| Pressure | 2–4.5 bar | ||||||
| Port size | G1/2 | G1/2 | G3/4 | G1 | G1 | G1-1/4 | |
| Dimensions, water-cooled cm | 50×40×95 | 50×40×95 | 60×45×125 | 75×55×145 | 85×55×145 | 90×65×155 | |
| Dimensions, air-cooled cm | 50×40×95 | 60×45×125 | 75×55×145 | 85×55×145 | 90×65×155 | 115×75×175 | |
| Weight, air-cooled kg | 95 | 115 | 155 | 225 | 315 | 450 | |
| Enclosure | Powder-coated cold-rolled steel (standard RAL 9016, SUS304 optional) | ||||||
| Power supply ph/v/Hz | 1/220/50 | 3/380/50 | |||||
| Connected load kW (excl. heater) | 1.6 | 2.3 | 3.5 | 5 | 6.5 | 11 | |
| Option 1 | Flow measurement and control with flow sensor and regulating valve, model suffix F | ||||||
| Option 2 | For compressed-air supply, a built-in or external regenerative air dryer is available down to a -70℃ dew point, model suffix D | ||||||
| Option 3 | High/low-temperature version available, model suffix H, range extendable to -40 to 200℃ | ||||||
※ Notes
- Cooling capacities are based on 20℃ cooling-water inlet temperature; air-cooled units at 20℃ ambient.
- Only part of the product range is listed. For other models or customised requirements please contact our sales team. Specifications are subject to change without notice.
SpecificationsPTLQ Series -60℃
| Model | PTLQ-D05-30 | PTLQ-D1-60 | PTLQ-D1.5-90 | PTLQ-D2.5-150 | PTLQ-D3.5-200 | PTLQ-D5.5-300 | |
|---|---|---|---|---|---|---|---|
| Min. process temperature | -60℃ | ||||||
| Gas capacity m³/h | 30 | 60 | 90 | 150 | 200 | 300 | |
| Cooling capacity kW @-55℃ | 0.5 | 1 | 1.5 | 2.5 | 3 | 5.5 | |
| Heating power kW (option) | 0.9 | 1.8 | 1.8 | 3 | 3.5 | 5.5 | |
| Control accuracy | ±0.5℃ (requires the optional heater; without it the unit runs uncontrolled and simply reaches the designed minimum outlet temperature) | ||||||
| Control system | PLC controller with intelligent PID temperature module for precise control and real-time display | ||||||
| HMI | 7-inch colour touchscreen, Chinese/English UI, intuitive operation, displays and logs temperature curves and test data | ||||||
| Controlled variable | Unit outlet temperature control | ||||||
| Communication | Modbus RTU protocol over RS485 | ||||||
| External inputs | External temperature sensor port, USB data port | ||||||
| Temperature feedback | PT100 feedback on the heat-transfer medium (inlet and outlet temperature) | ||||||
| Protection | Real-time status display and automatic fault diagnosis with multi-level alarms: power failure, compressor overload, high/low refrigerant pressure, heater over-temperature, temperature module fault and sensor fault. | ||||||
| Heat-exchanger material | SUS304 | ||||||
| Heat-exchanger rating | ≥3 MPa | ||||||
| Inlet gas requirement | Nitrogen or 3–7 bar compressed air; must be dried, with a dew point below the minimum process temperature | ||||||
| Refrigerant | Stage 1 R404A / Stage 2 R23 | ||||||
| Port size | 10mm卡套 | G1/2 | G3/4 | G1 | G1-1/4 | DN50 | |
| Water-cooled (suffix W) | Flow m³/h | 1.2 | 1.8 | 2.5 | 3.5 | 4.5 | 6.5 |
| Water temp. | Flow rates are calculated at 20℃ water temperature. Cooling water inlet must stay between 5℃ and 30℃, otherwise unit operation is affected. | ||||||
| Pressure | 2–4.5 bar | ||||||
| Port size | G1/2 | G1/2 | G3/4 | G1 | G1-1/4 | G1-1/4 | |
| Dimensions, water-cooled cm | 60×45×115 | 75×55×145 | 85×55×145 | 90×65×155 | 115×75×175 | 125×85×195 | |
| Dimensions, air-cooled cm | 75×55×145 | 85×55×145 | 90×65×155 | 115×75×175 | 125×85×195 | 155×100×225 | |
| Weight, air-cooled kg | 135 | 180 | 225 | 305 | 385 | 455 | |
| Enclosure | Powder-coated cold-rolled steel (standard RAL 9016, SUS304 optional) | ||||||
| Power supply ph/v/Hz | 1/220/50 | 3/380/50 | |||||
| Connected load kW (excl. heater) | 2 | 3 | 4.5 | 6 | 8.5 | 12.5 | |
| Option 1 | Flow measurement and control with flow sensor and regulating valve, model suffix F | ||||||
| Option 2 | For compressed-air supply, a built-in or external regenerative air dryer is available down to a -70℃ dew point, model suffix D | ||||||
| Option 3 | High/low-temperature version available, model suffix H, range extendable to -60 to 200℃ | ||||||
※ Notes
- Cooling capacities are based on 20℃ cooling-water inlet temperature; air-cooled units at 20℃ ambient.
- Only part of the product range is listed. For other models or customised requirements please contact our sales team. Specifications are subject to change without notice.
SpecificationsPTLQ Series -80℃
| Model | PTLQ-F05-30 | PTLQ-F1-60 | PTLQ-F1.5-90 | PTLQ-F2.5-150 | PTLQ-F3.5-200 | PTLQ-F5.5-300 | |
|---|---|---|---|---|---|---|---|
| Min. process temperature | -80℃ | ||||||
| Gas capacity m³/h | 30 | 60 | 90 | 150 | 200 | 300 | |
| Cooling capacity kW @-75℃ | 0.5 | 1 | 1.5 | 2.5 | 3.5 | 5.5 | |
| Heating power kW (option) | 0.9 | 1.8 | 1.8 | 3 | 3.5 | 5.5 | |
| Control accuracy | ±0.5℃ (requires the optional heater; without it the unit runs uncontrolled and simply reaches the designed minimum outlet temperature) | ||||||
| Control system | PLC controller with intelligent PID temperature module for precise control and real-time display | ||||||
| HMI | 7-inch colour touchscreen, Chinese/English UI, intuitive operation, displays and logs temperature curves and test data | ||||||
| Controlled variable | Unit outlet temperature control | ||||||
| Communication | Modbus RTU protocol over RS485 | ||||||
| External inputs | External temperature sensor port, USB data port | ||||||
| Temperature feedback | PT100 feedback on the heat-transfer medium (inlet and outlet temperature) | ||||||
| Protection | Real-time status display and automatic fault diagnosis with multi-level alarms: power failure, compressor overload, high/low refrigerant pressure, heater over-temperature, temperature module fault and sensor fault. | ||||||
| Heat-exchanger material | SUS304 | ||||||
| Heat-exchanger rating | ≥3 MPa | ||||||
| Inlet gas requirement | Nitrogen or 3–7 bar compressed air; must be dried, with a dew point below the minimum process temperature | ||||||
| Refrigerant | Stage 1 R404A / Stage 2 R508B | ||||||
| Port size | 10mm卡套 | G1/2 | G3/4 | G1 | DN32 | DN50 | |
| Water-cooled (suffix W) | Flow m³/h | 1.5 | 2.3 | 3.2 | 4.5 | 5.6 | 8.2 |
| Water temp. | Flow rates are calculated at 20℃ water temperature. Cooling water inlet must stay between 5℃ and 30℃, otherwise unit operation is affected. | ||||||
| Pressure | 2–4.5 bar | ||||||
| Port size | G1/2 | G3/4 | G1 | G1-1/4 | G1-1/4 | DN40 | |
| Dimensions, water-cooled cm | 60×45×125 | 75×55×145 | 85×55×145 | 90×65×155 | 115×75×175 | 125×85×195 | |
| Dimensions, air-cooled cm | 75×55×145 | 85×55×145 | 90×65×155 | 115×75×175 | 125×85×195 | 155×100×225 | |
| Weight, air-cooled kg | 150 | 205 | 255 | 335 | 420 | 485 | |
| Enclosure | Powder-coated cold-rolled steel (standard RAL 9016, SUS304 optional) | ||||||
| Power supply ph/v/Hz | 1/220/50 | 3/380/50 | |||||
| Connected load kW (excl. heater) | 2.5 | 3.5 | 5 | 8.5 | 12 | 16 | |
| Option 1 | Flow measurement and control with flow sensor and regulating valve, model suffix F | ||||||
| Option 2 | For compressed-air supply, a built-in or external regenerative air dryer is available down to a -70℃ dew point, model suffix D | ||||||
| Option 3 | High/low-temperature version available, model suffix H, range extendable to -80 to 200℃ | ||||||
※ Notes
- Cooling capacities are based on 20℃ cooling-water inlet temperature; air-cooled units at 20℃ ambient.
- Only part of the product range is listed. For other models or customised requirements please contact our sales team. Specifications are subject to change without notice.
SpecificationsPTLQ Series -100℃
| Model | PTLQ-H05-30 | PTLQ-H1-60 | PTLQ-H1.5-90 | PTLQ-H2.5-150 | PTLQ-H3.5-200 | PTLQ-H5.5-300 | |
|---|---|---|---|---|---|---|---|
| Min. process temperature | -100℃ | ||||||
| Gas capacity m³/h | 30 | 60 | 90 | 150 | 200 | 300 | |
| Cooling capacity kW @-95℃ | 0.5 | 1 | 1.5 | 2.5 | 3.5 | 5.5 | |
| Heating power kW (option) | 0.9 | 1.8 | 1.8 | 3 | 3.5 | 5.5 | |
| Control accuracy | ±0.5℃ (requires the optional heater; without it the unit runs uncontrolled and simply reaches the designed minimum outlet temperature) | ||||||
| Control system | PLC controller with intelligent PID temperature module for precise control and real-time display | ||||||
| HMI | 7-inch colour touchscreen, Chinese/English UI, intuitive operation, displays and logs temperature curves and test data | ||||||
| Controlled variable | Unit outlet temperature control | ||||||
| Communication | Modbus RTU protocol over RS485 | ||||||
| External inputs | External temperature sensor port, USB data port | ||||||
| Temperature feedback | PT100 feedback on the heat-transfer medium (inlet and outlet temperature) | ||||||
| Protection | Real-time status display and automatic fault diagnosis with multi-level alarms: power failure, compressor overload, high/low refrigerant pressure, heater over-temperature, temperature module fault and sensor fault. | ||||||
| Heat-exchanger material | SUS304 | ||||||
| Heat-exchanger rating | ≥3 MPa | ||||||
| Inlet gas requirement | Nitrogen or 3–7 bar compressed air; must be dried, with a dew point below the minimum process temperature | ||||||
| Refrigerant | Mixed refrigerant | ||||||
| Port size | 10mm卡套 | G1/2 | G3/4 | G1 | DN32 | DN50 | |
| Water-cooled (suffix W) | Flow m³/h | 2.2 | 3.5 | 5.3 | 8.5 | 11 | 15 |
| Water temp. | Flow rates are calculated at 20℃ water temperature. Cooling water inlet must stay between 5℃ and 30℃, otherwise unit operation is affected. | ||||||
| Pressure | 2–4.5 bar | ||||||
| Port size | G3/4 | G1 | G1-1/4 | DN40 | DN40 | DN50 | |
| Dimensions, water-cooled cm | 75×55×145 | 85×55×145 | 90×60×155 | 100×70×175 | 100×70×175 | 150×95×190 | |
| Dimensions, air-cooled cm | 90×65×155 | 100×70×175 | 125×85×185 | 150×95×190 | 150×95×190 | 200×150×225 | |
| Weight, air-cooled kg | 255 | 325 | 420 | 535 | 650 | 1050 | |
| Enclosure | Powder-coated cold-rolled steel (standard RAL 9016, SUS304 optional) | ||||||
| Power supply ph/v/Hz | 3/380/50 | ||||||
| Connected load kW (excl. heater) | 4.8 | 7.5 | 11 | 18 | 30 | 48 | |
| Option 1 | Flow measurement and control with flow sensor and regulating valve, model suffix F | ||||||
| Option 2 | For compressed-air supply, a built-in or external regenerative air dryer is available down to a -70℃ dew point, model suffix D | ||||||
| Option 3 | High/low-temperature version available, model suffix H, range extendable to -100 to 200℃ | ||||||
※ Notes
- Cooling capacities are based on 20℃ cooling-water inlet temperature; air-cooled units at 20℃ ambient.
- Only part of the product range is listed. For other models or customised requirements please contact our sales team. Specifications are subject to change without notice.
SpecificationsPTLQ Series -120℃
| Model | PTLQ-J05-30 | PTLQ-J1-60 | PTLQ-J1.5-90 | PTLQ-J2.5-150 | PTLQ-J3.5-200 | PTLQ-J5.5-300 | |
|---|---|---|---|---|---|---|---|
| Min. process temperature | -120℃ | ||||||
| Gas capacity m³/h | 30 | 60 | 90 | 150 | 200 | 300 | |
| Cooling capacity kW @-115℃ | 0.5 | 1 | 1.5 | 2.5 | 3.5 | 5.5 | |
| Heating power kW (option) | 0.9 | 1.8 | 1.8 | 3 | 3.5 | 5.5 | |
| Control accuracy | ±0.5℃ (requires the optional heater; without it the unit runs uncontrolled and simply reaches the designed minimum outlet temperature) | ||||||
| Control system | PLC controller with intelligent PID temperature module for precise control and real-time display | ||||||
| HMI | 7-inch colour touchscreen, Chinese/English UI, intuitive operation, displays and logs temperature curves and test data | ||||||
| Controlled variable | Unit outlet temperature control | ||||||
| Communication | Modbus RTU protocol over RS485 | ||||||
| External inputs | External temperature sensor port, USB data port | ||||||
| Temperature feedback | PT100 feedback on the heat-transfer medium (inlet and outlet temperature) | ||||||
| Protection | Real-time status display and automatic fault diagnosis with multi-level alarms: power failure, compressor overload, high/low refrigerant pressure, heater over-temperature, temperature module fault and sensor fault. | ||||||
| Heat-exchanger material | SUS304 | ||||||
| Heat-exchanger rating | ≥3 MPa | ||||||
| Inlet gas requirement | Nitrogen or 3–7 bar compressed air; must be dried, with a dew point below the minimum process temperature | ||||||
| Refrigerant | Mixed refrigerant | ||||||
| Port size | 10mm卡套 | G1/2 | G3/4 | G1 | DN32 | DN50 | |
| Water-cooled (suffix W) | Flow m³/h | 3.5 | 5.5 | 10 | 15 | 20 | 30 |
| Water temp. | Flow rates are calculated at 20℃ water temperature. Cooling water inlet must stay between 5℃ and 30℃, otherwise unit operation is affected. | ||||||
| Pressure | 2–4.5 bar | ||||||
| Port size | G1 | G1-1/4 | DN40 | DN50 | DN50 | DN65 | |
| Dimensions, water-cooled cm | 90×60×155 | 100×70×175 | 100×70×175 | 150×95×190 | 150×95×190 | 200×150×225 | |
| Dimensions, air-cooled cm | 125×85×185 | 150×95×190 | 150×95×190 | 200×150×225 | 200×150×225 | 250×180×255 | |
| Weight, air-cooled kg | 420 | 535 | 650 | 1050 | 1180 | 1550 | |
| Enclosure | Powder-coated cold-rolled steel (standard RAL 9016, SUS304 optional) | ||||||
| Power supply ph/v/Hz | 3/380/50 | ||||||
| Connected load kW (excl. heater) | 6 | 10.5 | 17 | 28 | 45 | 56 | |
| Option 1 | Flow measurement and control with flow sensor and regulating valve, model suffix F | ||||||
| Option 2 | For compressed-air supply, a built-in or external regenerative air dryer is available down to a -70℃ dew point, model suffix D | ||||||
| Option 3 | High/low-temperature version available, model suffix H, range extendable to -120 to 200℃ | ||||||
※ Notes
- Cooling capacities are based on 20℃ cooling-water inlet temperature; air-cooled units at 20℃ ambient.
- Only part of the product range is listed. For other models or customised requirements please contact our sales team. Specifications are subject to change without notice.
Need selection advice for the PTLQ?
Send us your temperature, heat load and flow requirement — an engineer will reply within one working day